1.
J Hazard Mater ; 459: 132101, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37487332

RESUMEN

For the first time, a continuous flow solar photo-Fenton demonstration plant has been assessed for wastewater reclamation according to the EU 2020/741 regulation. The treated water qualities achieved under two operating strategies (acidic and neutral pH) in a 100-m2 raceway pond reactor were explored in terms of liquid depth, iron source, reagent concentrations, and hydraulic residence time over three consecutive days of operation. The results obtained at acidic pH showed removal percentages of contaminants of emerging concern (CECs) > 75% and water quality classes B, C and D according to EU regulation at both assessed operating conditions, with treatment capacities up to 1.92 m3 m-2 d-1. At neutral pH with ferric nitrilotriacetate (Fe3+-NTA), 50% of CEC removal and only water quality class D were achieved with the most oxidizing condition assessed, giving a treatment capacity of 0.80 m3 m-2 d-1. The treatment capacities obtained in this work, which have never been achieved with solar water treatments, demonstrate the potential of this technology for commercial-scale application.

2.
Water Res ; 205: 117686, 2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34600227

RESUMEN

Simultaneous microorganism inactivation and organic microcontaminant removal in municipal wastewater treatment plant (WWTP) secondary effluents by the solar photo-Fenton process mediated by Fe3+-NTA is studied in depth. To achieve this objective, different key aspects were addressed: (i) the effect of initial Fe3+-NTA concentration at 1:1 molar ratio (0.10-0.30 mM) and H2O2 concentration (1.47-5.88 mM), (ii) the effect of initial microorganism load (103 and 106 CFU/mL) and (iii) the impact of the disinfection target on treatment cost. The first stage of this work was carried out in simulated WWTP effluent spiked with 100 µg/L of imidacloprid (IMD) as model microcontaminant and inoculated with Escherichia coli (E. coli) K-12 as reference strain, in a pilot scale raceway pond reactor with 5-cm of liquid-depth. Secondly, the most cost-effective conditions were validated in actual WWTP effluent. The kinetic analysis revealed that increasing Fe3+-NTA concentration over 0.20 mM does not significantly reduce treatment time due to the limited effect caused on the volumetric rate photon absorption. Treatment cost is determined by the disinfection process, since IMD removal was always faster than E. coli inactivation. The most cost-effective strategy to achieve 10 CFU/100 mL of E. coli (Regulation EU 2020/741) was 0.20/4.41 mM Fe3+-NTA/H2O2, with a cost of 0.32 €/m3. A less restrictive disinfection target, 100 CFU/100 mL, allowed reducing reactant concentration and cost, 0.10/1.47 mM Fe3+-NTA/H2O2 and 0.15 €/m3, respectively. In both cases, no regrowth at 24 h and more than 90% of IMD removal were observed.


Asunto(s)
Aguas Residuales , Purificación del Agua , Desinfección , Escherichia coli , Peróxido de Hidrógeno , Hierro , Cinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...